Dell OMSA Non-Certified Drive Flag: Difference between revisions

From DFWLPiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 12: Line 12:
NonDellCertifiedFlag=yes </nowiki>
NonDellCertifiedFlag=yes </nowiki>


Change to no.  Restart OpenManage services.
Change to no.  Restart OpenManage services. use admin powershell:
restart-service dcstor64

Revision as of 13:02, 18 June 2023

Turn off non-certified disk alert in OpenManage:

Esxi

/etc/cim/dell/srvadmin/srvadmin-storage/stsvc.ini

Windows

C:\Program Files\Dell\SysMgt\sm\stsvc.ini

Loate the below line, it is generally near the top.

; nonDellCertified flag for blocking all non-dell certified alerts.
NonDellCertifiedFlag=yes 

Change to no. Restart OpenManage services. use admin powershell:

restart-service dcstor64