Dell OMSA Non-Certified Drive Flag: Difference between revisions

From DFWLPiki
Jump to navigation Jump to search
(Created page with "Turn off non-certified disk alert in OpenManage: Esxi /etc/cim/dell/srvadmin/srvadmin-storage/stsvc.ini Windows C:\Program Files\Dell\SysMgt\sm\stsvc.ini Loate the below l...")
 
No edit summary
 
(5 intermediate revisions by the same user not shown)
Line 1: Line 1:
[[Category:Dell Servers]]
Turn off non-certified disk alert in OpenManage:
Turn off non-certified disk alert in OpenManage:


Line 5: Line 6:
Windows
Windows
  C:\Program Files\Dell\SysMgt\sm\stsvc.ini
  C:\Program Files\Dell\SysMgt\sm\stsvc.ini
Linux
/opt/dell/srvadmin/etc/srvadmin-storage/stsvc.ini


Loate the below line, it is generally near the top.
Loate the below line, it is generally near the top.
Line 11: Line 14:
NonDellCertifiedFlag=yes </nowiki>
NonDellCertifiedFlag=yes </nowiki>


Change to no.  Restart OpenManage services.
Change to no.  Restart OpenManage services. use admin powershell:
restart-service dcstor64 -force

Latest revision as of 23:32, 3 January 2024

Turn off non-certified disk alert in OpenManage:

Esxi

/etc/cim/dell/srvadmin/srvadmin-storage/stsvc.ini

Windows

C:\Program Files\Dell\SysMgt\sm\stsvc.ini

Linux

/opt/dell/srvadmin/etc/srvadmin-storage/stsvc.ini

Loate the below line, it is generally near the top.

; nonDellCertified flag for blocking all non-dell certified alerts.
NonDellCertifiedFlag=yes 

Change to no. Restart OpenManage services. use admin powershell:

restart-service dcstor64 -force